The Journal of Korean Academic Society of Nursing Education 2006;12(2):265-271.
Published online December 31, 2006.
Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test
Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong;
1Chungbuk National University Hospital
2Department of Nursing, Munkyung College
3Department of Biomedical Engineering, School of Medicine, Chungbuk National University & CBITRC
4Department of Laboratory Medicine, Chung-Ang University College of Medicine
5Department of Nursing Science, Oriental Medical College, Daejeon University
6Department of Nursing Science, Oriental Medical College, Daejeon University
7Department of Biomedical Engineering, School of Medicine, Chungbuk National University & CBITRC
8Department of Biomedical Engineering, School of Medicine, Chungbuk National University & CBITRC
혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석
박미숙, 박경순, 김경아, 차영주, 전명희, 김태임, , 차은종
1충북대학교병원
2문경대학 간호과
3충북대학교 의과대학 의공학교실
4중앙대학교 의과대학
5대전대학교 한의과대학 간호학과
6대전대학교 한의과대학 간호학과
7
8충북대학교 의과대학 의공학교실
Abstract
Purpose
To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.
Key Words: Vacuum assisted auto-lancing device, Micro blood volume measurement, Pain measurement, Blood glucose test
 
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 582 View
  • 0 Download
Related articles in J Korean Acad Soc Nurs Educ


ABOUT
BROWSE ARTICLES
FOR CONTRIBUTORS
Editorial Office
Department of Nursing, Chungbuk National University
1 Chungdae-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do, 28644, Korea
Tel: +82-43-249-1712    E-mail: spark2020@chungbuk.ac.kr                

Copyright © 2024 by The Korean Academic Society of Nursing Education.

Developed in M2PI

Close layer
prev next